Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 622
Filtrar
1.
Prog Orthod ; 25(1): 13, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584176

RESUMO

OBJECTIVES: To evaluate the accuracy of a semi-automatic 3D digital setup process in predicting the orthodontic treatment outcome achieved by labial fixed appliances. SUBJECTS AND METHODS: Twenty-five adult patients (18 to 24 years old) with class I malocclusion and moderate crowding were prospectively enrolled and received treatment on both jaws through the straight-wire technique. Prior to treatment commencement, a semi-automatic digital setup simulating the predicted treatment outcome was performed for each patient through Orthoanalyzer software (3Shape®, Copenhagen, Denmark) to obtain the prediction model. This was compared to the final outcome model through 3D superimposition methods. Metric variables and inspection of color-coded distance maps were used to detect how accurately the digital setup predicts the actual treatment outcome. RESULTS: The mean absolute distances (MAD) between the superimposed dental arches of the predicted and the final models were: 0.77 ± 0.13 mm following superimposition on the palate, 0.52 ± 0.06 mm following superimposition on the maxillary dental arch, and 0.55 ± 0.15 mm following superimposition on the mandibular dental arch. The MAD at the palatal reference area was 0.09 ± 0.04 mm. Visualization of color-coded distance maps indicated that the digital setup accurately predicted the final teeth position in a few cases. Almost half of the cases had posteriorly wider upper and lower dental arches and palatally/lingually positioned or inclined anterior teeth, whereas the rest still showed errors within 2-3 mm, distributed over the entire dental arches with no distinct pattern. CONCLUSIONS: The accuracy of semi-automatic prediction of the labial fixed appliance treatment outcome in Class I cases with moderate crowding is not yet sufficient. While average measures showed deviations less than 1 mm, examination of individual color-coded distance maps revealed significant disparities between the simulated and the actual results.


Assuntos
Má Oclusão Classe I de Angle , Má Oclusão , Dente , Adulto , Humanos , Adolescente , Adulto Jovem , Estudos Prospectivos , Má Oclusão/terapia , Má Oclusão Classe I de Angle/terapia , Aparelhos Ortodônticos Fixos , Aparelhos Ortodônticos
2.
Clin Oral Investig ; 28(5): 249, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607436

RESUMO

OBJECTIVE: To critically appraise and assess the currently observed evidence about the difference in orthodontic treatment duration between clear aligners and fixed appliances in crowding cases. MATERIALS AND METHODS: An electronic search without limitations was conducted from inception to June 2023 covering nine databases: The Cochrane Central Register of Controlled Trials (CENTRAL), PubMed, Scopus, Web of Science, Google Scholar, Trip, CINAHL via EBSCO, EMBASE via OVID and ProQuest. Randomized controlled trials (RCTs) and matched non-randomized studies were included in this systematic review. Risk of Bias was assessed via Cochrane's tool (RoB 2) for RCTs and ROBINS-I tool for non-randomized studies. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) framework was employed to evaluate the overall quality of evidence. RESULTS: Out of the 3537 articles initially identified, ten eligible studies were included in this systematic review; six were RCTs. Only one study offered extraction-based treatment, while the other nine adopted non-extraction treatments. According to the GRADE, there is low evidence that treatment duration in mild to moderate crowding cases with clear aligners is similar to that in fixed orthodontic appliances. Meta-analysis was not administered due to high inconsistency. CONCLUSIONS: Based on currently available information, there was no significant difference in the treatment duration between the CA and FA groups in mild to moderate crowding cases. Further well-performed RCTs, especially in severe cases, are required. CLINICAL RELEVANCE: Time efficiency is an essential outcome measure for clinical orthodontic practice. While the type of appliance used is a critical determinant of treatment duration, orthodontists should be aware of other factors that can significantly impact treatment time, such as patient and treatment-related factors.


Assuntos
Assistência Odontológica , Aparelhos Ortodônticos Removíveis , Humanos , Duração da Terapia , Aparelhos Ortodônticos Fixos
3.
Cureus ; 16(3): e55911, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38601407

RESUMO

Background Attachments play a vital role in aligner-led orthodontic therapy, first passively through retention of the appliance and secondly, through bringing about tooth movement, by virtue of its active surfaces, to achieve treatment goals. Additionally, irregularities on the surface of attachments attract plaque adhesion. Thus the effect of brushing with different toothbrushes on the surface of attachments is an important factor to study. This would allow clinicians to better advise patients who are undergoing aligner therapy. Four types of brushes are available commercially, namely hard, medium, soft, and ultra-soft. This study analyses the interaction between the kind of toothbrush used and the wear of the surface of the aligner attachment, to understand the impact of a toothbrush on the attachment. Aim To observe the surface wear and change in the shape of the aligner attachment on brushing with four varying hardness of toothbrush bristle (ultra-soft, soft, medium, and hard) over six months to three years. Material and methods One attachment was bonded to the buccal surface of extracted premolars. One tooth with attachment was subjected to SEM analysis and the rest were divided into four groups of five teeth each, based on the type of toothbrush to be used. Brushing with hard, medium, soft, and ultra-soft toothbrushes was carried out in a brushing simulator in two cycles simulating six months, one year, 18 months, and three years of brushing. A contact profilometer was used to evaluate surface roughness before and after brushing and pre- and post-surface roughness values were compared to quantitate changes after which SEM analysis was carried out for qualitative assessment of the surface of the samples. The Shapiro-Wilks test was applied to evaluate the normality of the data, followed by the one-way ANOVA, and statistical significance was applied at p<0.05. Results At six months, the samples brushed with the medium toothbrush showed the least surface roughness (0.2±0.192) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (1.9±0.159). At one year, the samples brushed with the soft toothbrush showed the least surface roughness (0.46 ±0.31) and those brushed with the ultra-soft toothbrushes showed the highest surface roughness (2.12 ±0.12). At the 1.5-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.43±0.39) and the highest in the soft toothbrush group (1.6± 0.41). At the three-year point, the surface roughness of the samples was lowest in the ultra-soft toothbrush group (0.28 ± 0.17) and the highest in the medium toothbrush group (1.6 ± 0.31). Conclusion Ultra-soft toothbrushes have a high abrasive potential, as seen by higher surface roughness values over six months and one year. Morphometric changes were the most noticeable for attachments brushed by hard-bristled toothbrushes and medium-bristled brushes.

4.
Prog Orthod ; 25(1): 15, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644413

RESUMO

BACKGROUND: External apical root resorption (EARR) is a frequently observed adverse event in patients undergoing fixed appliance therapy. Assessing the patients' risk during treatment is important, as certain factors are assumed to be associated with an increased likelihood of occurrence. However, their predictive value remains limited, making evidence-based clinical decision-making challenging for orthodontists. To address this issue, the Dutch Association of Orthodontists (NvVO) developed a clinical practice guideline (CPG) for EARR in accordance with the AGREE II instrument (Appraisal of Guidelines for Research and Evaluation II) in 2018. The aim of this study is to get insight into the actual utilization and the practical implementation of the guideline among orthodontists. The hypothesis to be tested was that after its introduction, clinical practice for EARR has changed towards the recommendations in the CPG. OBJECTIVE: To investigate the use of the 2018 clinical practice guidelines for EARR among orthodontists 3 years after its introduction. METHODS: A questionnaire using a 7-point Likert scale was developed concerning four domains of EARR described in the guideline. The questionnaire was piloted, finalised, and then distributed digitally among Dutch orthodontists. REDCap was used for data collection, starting with an invitation email in June 2021, followed by two reminders. Effect was tested by the Mann-Whitney U test, and the influence of demographic variables was analysed. RESULTS: Questionnaires were sent out to all 275 and completed by 133 (response rate 48%); N = 59 females and N = 73 males were included; 81% had their training in the Netherlands, 89% had ≥ 6 years of work experience, and 89% worked in private orthodontic practice. One hundred thirty orthodontists (98.5%) reported changes in clinical practice. The biggest positive change in clinical behaviour regarding EARR occurred if EARR was diagnosed during treatment. Sex, clinical experience, country of specialist training, and working environment of the respondents did not affect clinical practices regarding EARR. CONCLUSIONS: This questionnaire demonstrated that, 3 years after introduction of the guideline, orthodontists improved their self-reported clinical practices to a more standardised management of root resorption. None of the demographic predictors had a significant effect on the results.


Assuntos
Ortodontistas , Guias de Prática Clínica como Assunto , Reabsorção da Raiz , Humanos , Feminino , Masculino , Padrões de Prática Odontológica , Países Baixos , Inquéritos e Questionários , Adulto , Ápice Dentário/patologia , Fidelidade a Diretrizes
5.
Int J Dent Hyg ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659166

RESUMO

OBJECTIVES: This study aimed to determine the overall oral health statuses of patients with fixed orthodontic appliance and clear aligner, as well as their oral hygiene management behaviours and satisfaction. METHODS: We selected 40 participants (20 each with fixed orthodontic devices and clear aligners) who visited a dental clinic. We conducted a survey to determine the oral hygiene management behaviours of the subjects and their satisfaction with their orthodontic treatment. Three measurements were also conducted at 4-week intervals to determine the oral health statuses of the subjects. RESULTS: The Löe and Silness gingival index of patients with fixed orthodontic appliances indicated moderate gingivitis (1.1 ± 0.3), and those with clear aligners had mild gingivitis (0.6 ± 0.4) (p < 0.001). The modified O'Leary index also indicated that the degree of dental plaque deposition in the oral cavity was lower in patients treated with a clear aligner (43.0 ± 18.2 points) than in those treated with a fixed orthodontic (28.1 ± 10.9 points) (p = 0.004). Regarding oral hygiene management, the fixed orthodontic group received scaling more frequently (p = 0.006), received more oral health education (p < 0.001) and had a longer brushing time (p = 0.008) than the clear aligner group. No significant difference was observed in satisfaction between the fixed orthodontic appliance and the clear aligner. CONCLUSIONS: Regarding the oral health status by orthodontic appliance type, the clear aligner group had the advantages of reduction in dental plaque attachment and gingival health. The fixed orthodontic group exhibited better oral hygiene management behaviours. Satisfaction with orthodontic treatment was found to be similar for the two device types.

6.
Cureus ; 16(2): e54740, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38523938

RESUMO

Background With the advent of 3D printing, many more possibilities have arisen for treatment planning. 3D rapid prototyping has enabled us to see a whole other dimension that has helped us to give the best possible care for our patients. With more and more advancements being made in this subject, it becomes necessary to check the reliability of the equipment and its effectiveness in the management of the problem at hand. This original study was conducted with the aim of checking the accuracy, dimensional stability, and reliability of orthodontic retainers made on a conventional and digitally fabricated model over a six-month period after debonding. Material and methods The patients were selected from those who have completed fixed orthodontic mechanotherapy from the Department of Orthodontics and Dentofacial Orthopaedics, Sri Guru Ram Das Institute of Dental Sciences and Research, Sri Amritsar. Fifty patients received a clear retainer, which was fabricated for the upper and lower arch after removing the brackets. Patients were included in this study irrespective of their age groups. The manual method used a vacuum-forming machine to fabricate six retainers on stone models. In the digital method, new impressions were taken after three months, and digital models were obtained through 3D scanning and printing, followed by clear retainer fabrication. The data were gathered through a systematic process involving manual and digital methods for clear retainer fabrication and subsequent evaluation. The data obtained was computed for statistical evaluation and comparison. Results Mean and standard deviations of conventional (manual) and digital variables in the two groups were calculated. An ANOVA test was used to evaluate statistically significant differences for mesiodistal width and buccolingual width, and a post hoc Tuckey test was applied for multiple comparisons. The results indicated that most mesiodistal and buccolingual width measurements showed non-significant variations and exhibited a good correlation. Extraction space opening, assessed through an independent t-test for both the maxilla and mandible, also yielded non-significant and comparable results. Additionally, intra-operator and inter-operator measurements using a digital caliper demonstrated high agreement. Intra-class correlation (ICC) values exceeded 0.75, and inter-operator ICC results reflected a high level of agreement ranging from 0.8 to 0.99. Conclusion The primary objective of this study was to establish a correlation between the accuracy, dependability, and clinical efficacy of orthodontic retainers produced using both conventional and digitally created models. This investigation spanned a duration of six months following the removal of orthodontic brackets. The results showed that most of the statistically significant values were due to the inherent potential of the 3D printer for polymerization shrinkage, which, being a stereolithographic 3D printer, had a potential for a slight dimensional shift in the transverse dimension. However, the mean difference between all the models printed was slight and clinically insignificant.

7.
Dent Res J (Isfahan) ; 21: 6, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38425319

RESUMO

Background: The objective is to compare the impact of clear aligner treatment (CAT) versus conventional fixed appliance treatment (FAT) on oral health-related quality of life (OHRQoL) among adults at five-time points: pretreatment (T0), 1 week (T1), 1 month after (T2), and 6 months after (T3) treatment initiation, and in the long-term follow-up (T4). Materials and Methods: Search terms were based on Medical Subject Headings (MeSH) and non-MeSH. Potentially eligible studies compared OHRQoL in clear aligner (CA) and fixed appliance (FA) patients. In February 2023, Scopus, Web of Science, Cochrane, and PubMed were searched for published studies. Nine out of 94 shortlisted papers were eligible for a systematic review. Of these nine papers, five studies were considered for a meta-analysis. Results: At T0, CA and FA patients had similar oral health impact profile (OHIP)-14 questionnaire scores with a standard mean difference (SMD) of 0.105 (confidence interval [CI]: -1.029-1.48). The SMD of the OHRQoL related to T1, T2, and T3 was -3.119 (CI: -0.145, 0.355), -1.527 (CI: -5.597, -0.64), and - 2.331 (CI: -1.906, -1.148). T4 showed no difference between groups (SMD = 0.007, CI: CI: -4.286, -0.376). Regarding the OHIP-14 domains, functional limitations remained consistent in both groups across all time intervals. Psychological discomfort exhibited a notable difference only at T2. Throughout the treatment, CAT showed significantly lower levels of physical, psychological, and social disability, as well as handicap, though these differences did not persist beyond T4. Notably, physical pain was the sole domain that remained elevated in the FAT group up to T4. Conclusion: During the 1st day of the orthodontic treatment, both the CA and FA groups had comparable OHRQoL statuses. However, as time passed, the CA group notably improved their OHRQoL compared to the FA group. Interestingly, after a year or the completion of treatment, both groups eventually reached similar OHRQoL levels. Nevertheless, it is worth noting that FA patients continued to experience more physical pain even a year later.

8.
Prog Orthod ; 25(1): 6, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38342823

RESUMO

BACKGROUND: This single-centered randomized controlled clinical trial aimed to evaluate the effectiveness of micro-osteoperforations (MOPs) in accelerating the orthodontic retraction of maxillary incisors. METHODS: Forty-two patients aged 16-40 were recruited and randomly assigned into two groups, one which underwent MOPs (MOPG) in the buccal and palatal region of all maxillary incisors immediately before the start of retraction and one which did not (CG). Eligibility criteria included the orthodontic need for maxillary first premolars extraction and space closure in two phases. The primary outcome of the study consisted of measuring the rate of space closure and, consequently, the rate of incisors' retraction using digital model superimposition 14 days later and monthly thereafter for the next 4 months. The secondary outcomes included measuring anchorage loss, central incisors' inclination, and root length shortening, analyzed using cone beam computed tomography scans acquired before retraction and 4 months after retraction. Randomization was performed using QuickCalcs software. While clinical blinding was not possible, the image's examinator was blinded. RESULTS: Twenty-one patients were randomly assigned to each group. However, due to various reasons, a total of 37 patients (17 male and 20 female) were analyzed (mean age: 24.3 ± 8.1 years in the MOPG; 22.2 ± 4.2 years in the CG) during the trial. No statistically significant difference was found between the MOPG and the CG regarding the incisors' retraction measured at different time points at the incisal border (14 days, 0.4 mm vs. 0.5 mm; 1 month, 0.79 mm vs. 0.77 mm; 2 months, 1.47 mm vs. 1.41 mm; 3 months, 2.09 mm vs. 1.88 mm; 4 months, 2.62 mm vs. 2.29 mm) and at the cervical level (14 days, 0.28 mm vs. 0.30 mm; 1 month, 0.41 mm vs. 0.32 mm; 2 months, 0.89 mm vs. 0.61 mm; 3 months, 1.36 mm vs. 1.10 mm; 4 months, 1.73 mm vs. 1.39 mm). Similarly, no statistically significant differences were detected in the space closure, anchorage loss, central incisors' inclination, and radicular length between groups. No adverse effect was observed during the trial. CONCLUSIONS: MOPs did not accelerate the retraction of the maxillary incisors, nor were they associated with greater incisor inclination or root resorption. Trial registration ClinicalTrials.gov NCT03089996. Registered 24 March 2017- https://clinicaltrials.gov/ct2/show/NCT03089996 .


Assuntos
Incisivo , Reabsorção da Raiz , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Fechamento de Espaço Ortodôntico , Técnicas de Movimentação Dentária/métodos , Tomografia Computadorizada de Feixe Cônico , Dente Pré-Molar/cirurgia , Maxila
9.
Clin Exp Dent Res ; 10(1): e827, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38345490

RESUMO

BACKGROUND: Fabricating clear aligners by thermoforming three-dimensional printed dental models requires a high degree of accuracy. It is unknown whether model thickness affects the accuracy when used to thermoform aligners. PURPOSE: This research utilizes three-dimensional printed models made with differing wall thicknesses to determine its effect on their ability to withstand deformation during aligner fabrication. METHODS: A total of 50 models of different wall thickness (10 each of 0.5, 1.0, 1.5, 2.0 mm, and solid) were printed using model resin (Model V2, Formlabs) on a low-force stereolithography printer (Form 3B, Formlabs). Aligners were then fabricated using a thermal pressure forming machine (Biostar V, Great Lakes Dental Technologies) utilizing 25 s cycles to adapt 0.030″ acrylic sheets (Invisacryl, Great Lakes Dental Technologies), then removed from the models and sprayed with a contrast powder (Optispray, Dentsply Sirona) to aid in scanning with an intraoral scanner (CEREC Primescan, Dentsply Sirona). Each aligner's data was then compared to the original file used for printing with 3D comparison software (Geomagic Control X, 3D Systems). RESULTS: The results show model thickness greater than or equal to 2.0 mm produced clinically acceptable results within the margin of error (0.3 mm). A total of 0.5 mm thickness failed to withstand thermal forming in 4 of the 10 trials. A total of 0.5 mm produced 27.56% of results in tolerance, 1.0 mm produced 75.66% of results in tolerance, 1.5 mm had 80.38% of results in tolerance, 86.82% of 2 mm models were in tolerance, and solid had 96.45% of results in tolerance. CONCLUSION: Hollow models of thicknesses 2.0 mm and solid models produced clinically acceptable aligners while utilizing less resin per unit compared to solid models, thus being more cost effective, time efficient and eco-friendly. Therefore, a recommendation can be made to print hollow models with a shell thickness of greater than 2.0 mm for aligner fabrication.


Assuntos
Polimetil Metacrilato , Impressão Tridimensional , Software
10.
J Orthod ; : 14653125241229456, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323415

RESUMO

OBJECTIVE: To evaluate the knowledge and preference of patients treated at a Dental School in Jaraguá do Sul, Brazil, about using aligners and the reasons for choosing this device as a treatment option. DESIGN: A cross-sectional study. PARTICIPANTS: A total of 82 participants aged 18-45 years recruited at a screening clinic. METHODS: A questionnaire was completed in person using a tablet with digital forms. RESULTS: Almost half of the participants (49%) knew about aligners; 40% were aged 18-24 years, and 77% were female. When observing the images of the types of orthodontic appliances, the aligners had an acceptance rate of 80%. Among the reasons that led to the preference for choosing aligners, 68% cited aesthetics and 42% comfort. CONCLUSION: Recently, clear aligners have become a popular choice for orthodontic treatment, particularly among adults. Despite their popularity and effectiveness, many patients still need more information about aligner treatment. Over half of the respondents did not know what orthodontic aligners were. Younger participants had more knowledge about aligners than older participants. Patients still need more knowledge about the types of appliances available for orthodontic treatment. When presented with images of the kinds of devices available, almost 80% of participants showed greater satisfaction with aligners.

11.
BMC Oral Health ; 24(1): 191, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317101

RESUMO

AIM: There is limited research on the clinical performance of double-thread orthodontic miniscrews. This study aimed to compare the stability of double-thread and single-thread orthodontic miniscrews and identify the potential associations between patient-related and location-related factors with miniscrew stability. METHODS: This retrospective cohort study involved 90 orthodontic miniscrews (45 single-thread, 45 double-thread) with identical dimensions (8 mm length, 1.6 mm diameter). The screws were inserted in various locations within the upper jaw of 83 patients (54 females, 29 males; mean age = 15.1 ± 2.4 years). Failure was defined as excessive mobility or loss of miniscrew after placement. The data recorded were patient age, gender, insertion site, side of insertion (buccal or lingual), duration of force application, and failure occurrence. RESULTS: The overall success rate within the sample was 92.2%. Double-thread miniscrews exhibited a significantly higher success rate than single-thread miniscrews (P = 0.049), with 97.8% and 86.7% success rates, respectively. Gender, age, insertion location, and side of insertion did not show significant associations with failure (P > 0.05). Log-rank analysis revealed a significant difference between the two groups (P = 0.046), indicating a higher probability of survival for the double-thread design. CONCLUSIONS: The overall success rate of orthodontic miniscrews was high in the present sample. Double-thread miniscrews placed in various locations within the maxillary arch demonstrated superior stability and survival rates compared to their single-thread counterparts. Therefore, double-thread miniscrews may be preferred when bone quality is inadequate, such as in young patients.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Desenho de Aparelho Ortodôntico , Masculino , Feminino , Humanos , Criança , Adolescente , Estudos Retrospectivos , Parafusos Ósseos , Maxila/cirurgia
12.
Orthod Craniofac Res ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321815

RESUMO

OBJECTIVE: To compare the anterior crowding correction after sequential use of the first 5 aligners between two aligner exchange protocols (7 and 14 days) in mature adult patients. MATERIALS AND METHODS: Thirty-six patients over 35 years who received orthodontic treatment with Invisalign® were randomly allocated to two different aligner replacement sequence protocols: Group 1: exchange every 7 days (n = 18); and Group 2: exchange every 14 days (n = 18). All patients were scanned with iTero Element 5D® (Align Technology) in two treatment times: at pre-treatment (T1) and after using the first five aligners (T2). Little's Irregularity Index (LII) and arch widths were evaluated with OrthoCAD software. Intra and intergroup comparisons were performed with the dependent and independent t-tests. The results were considered significant for P < .05. RESULTS: Thirty-five patients completed the study. Both groups' maxillary and mandibular Irregularity Indexesi were significantly lower at T2. There was no significant difference in inter-canine, inter-premolar, and intermolar distances. G2 (14 days) presented a greater decrease in mandibular irregularity than G1 (7 days). CONCLUSION: Both exchange protocols (7 and 14 days) effectively correct anterior crowding in the initial phase of orthodontic treatment with aligners in mature adult patients. However, the 14-day exchange protocol provided a greater correction in mandibular anterior crowding in the evaluated period than the 7-day exchange protocol.

13.
J Orofac Orthop ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378857

RESUMO

PURPOSE: The aim of this respectively cohort study was to evaluate the lower second and third molars and canine angulations, retromolar space and occlusal relationships after functional orthodontic treatments with the monoblock or Herbst appliance using panoramic radiographs. METHODS: Pre- and posttreatment cephalometric and panoramic radiographs of 133 patients (mean age 13.89 ± 1.14 years) treated non-extraction with monoblock (n: 44), Herbst (n: 45) and fixed orthodontic appliances (control group; n: 44) were included to the study. Dental and skeletal measurements were performed on cephalometric radiographs. The angle between the third and second molars, and canines with the lower border of the mandible and the occlusal plane, gonial angle, the angle between the third and second molars and the retromolar space width were assessed on pre- and posttreatment panoramic radiographs. Paired and independent t tests were used for the statistical analysis of the data for intragroup and intergroup comparisons. RESULTS: Functional treatment with both the monoblock and the Herbst appliances resulted in improvement of skeletal class II relationships. Retromolar space significantly increased in the functional appliance groups compared to the control group (p ≤ 0.001), but improvement of the angulations of posterior teeth was significant only in the monoblock group (p ≤ 0.001). CONCLUSION: While both the Herbst and monoblock appliances led to an increase in retromolar space, monoblock treatment resulted in more favorable angulation of the third molars compared to the Herbst treatment.

14.
Orthod Craniofac Res ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389292

RESUMO

OBJECTIVES: To compare self-reported pain levels across various treatment phases using passive self-ligating (Damon) and conventional (Victory) standardized fixed appliance systems. MATERIALS AND METHODS: Adolescents (12-17 years old) with crowding and displaced teeth, planned for non-extraction treatment, were recruited from four orthodontic clinics. They were randomized into stratified blocks (1:1 ratio) using concealed allocation to receive Damon Q™ (34 boys, 28 girls) or Victory™ (39 boys, 31 girls). Pain and analgesic intake were assessed on seven different occasions with validated self-report questionnaires using a 10-grade scale. RESULTS: Of the 132 patients included, six were lost to follow up. Clinically relevant mean pain scores (≥4) were registered in both groups after bonding upper and lower arches and after insertion of 0.019 × 0.025 stainless steel archwire. The highest mean scores were reported on day two after bonding the upper arch (Damon 5.96, Victory 7.18, P = .011). In both groups, at least 40% reported taking analgesics during various treatment phases. The Damon group reported a lower intake of analgesics on days one and two (P = .042 and .037) after treatment initiation. In the entire sample, boys reported significantly higher mean pain scores than girls on the second and third days after bonding (P = .008 and .026, respectively). CONCLUSIONS: Lower pain levels were reported from the Damon group after bonding. In general, boys reported higher pain than girls did. Clinicians and adolescents need to be aware that clinically relevant pain levels can be expected not only after bonding but also in later phases.

15.
Orthod Craniofac Res ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372469

RESUMO

OBJECTIVE: To evaluate the efficacy of microchips and 3D microsensors in the measurement of orthodontic forces. METHODS: Through September 2023, comprehensive searches were conducted on PubMed/MEDLINE, SCOPUS and SCIELO without restrictions. RESULTS: After removing duplicate entries and applying the eligibility criteria, 23 studies were included for analysis. All the studies were conducted in vitro, and slightly more than half of them were centred on evaluating orthodontic forces exerted by aligners. Eight utilized microchips as measurement tools, while the remaining studies made use of 3D microsensors for their assessments. In the context of fixed appliances, key findings included a high level of agreement in 3-dimensional orthodontic force detection between simulation results and actual applied forces. Incorporating critical force-moment combinations during smart bracket calibration reduced measurement errors for most components. Translational tooth movement revealed a moment-to-force ratio, aligning with the bracket's centre of resistance. The primary findings in relation to aligners revealed several significant factors affecting the forces exerted by them. Notably, the foil thickness and staging were found to have a considerable impact on these forces, with optimal force transmission occurring at a layer height of 150 µm. Furthermore, the type of material used in 3D-printing aligners influenced the force levels, with attachments proving effective in generating extrusive forces. Deliberate adjustments in aligner thickness were observed to alter the forces and moments generated. CONCLUSIONS: Microchips and 3D sensors provide precise and quantitative measurements of orthodontic forces in in vitro studies, enabling accurate monitoring and control of tooth movement.

16.
Orthod Craniofac Res ; 2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38247223

RESUMO

OBJECTIVE: This study aims to utilize the finite element method (FEM) to compare the dentoalveolar and mandibular effects associated with anterior mandibular repositioning using AdvanSync® (ADV) and Twin Block (TB). METHODS: A patient with Class II skeletal malocclusion and mandibular retrognathism was selected. A TB appliance was subsequently applied. Computed Tomography (CT) scans were acquired at the beginning of treatment (T1) and 8 months later (T2). Concurrently, a numerical TB model was validated through FEM simulations, which were compared with the T2 results. The ADV appliance was virtually simulated to evaluate stress and deformation on the condyle, symphysis, first lower molar and lower central incisors. RESULTS: Both simulations demonstrated significant mandibular advancement. However, ADV led to less incisor proclination and more molar intrusion compared to TB. ADV exhibited increased stress in the lower molar area, while TB had higher stress in the lower incisor region. Stress and deformations in the condyle and mandibular symphysis were similar in both simulations, with the highest stress observed at the condylar neck and the lowest at the upper pole of the condylar head. CONCLUSIONS: Both appliances achieved similar levels of mandibular advancement, with greater proclination of the lower central incisors and more widespread distribution of stress and molar intrusion when using ADV compared to TB.

17.
J Orofac Orthop ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180483

RESUMO

OBJECTIVE: The aim of this study is to assess the microbial contamination of three different brands of esthetic elastomeric ligatures. MATERIALS AND METHODS: Different brands of esthetic ligatures (Unistick Pearl [American Orthodontics, Sheboygan, WI, USA], Power Sticks Pearl [Ortho Technology, Tampa, FL, USA], and Ease [Obscure, 3M Unitek, Monrovia, CA, USA]) were randomly assigned to permanent canines of 25 patients (aged 11-18 years) undergoing corrective orthodontic treatment. After 30 days, the ligatures were removed, processed, and the biofilm composition was analyzed by checkerboard DNA-DNA hybridization for 40 bacterial species. The microbiological data were analyzed using a nonparametric mixed model. RESULTS: The ligatures presented intense microbial contamination after 30 days, but no statistically significant differences were observed among the three groups (p > 0.05). The levels of the evaluated individual species and proportions of the microbial complexes showed no statistically significant differences among the ligature groups (p > 0.05). CONCLUSIONS: Esthetic elastomeric ligatures became multicolonized by several bacterial species after 30 days of exposure to the oral cavity. However, no relevant differences were observed among the biofilm composition formed on the different ligature brands.

18.
Syst Rev ; 13(1): 43, 2024 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-38281057

RESUMO

OBJECTIVE: Since its introduction 25 years ago, the Invisalign® system has undergone multiple digital and biomechanical evolutions and its effectiveness is often compared to traditional systems without considering the many differences which characterize them. The main aim of this systematic review is to look at the literature dealing with studies on teeth movements using the Invisalign® system and the management of these movements through digital planning and artificial intelligence. MATERIALS AND METHODS: The following electronic databases were searched: MEDLINE, Embase, the Cochrane Oral Health Group's Trials Register, and CENTRAL. Unpublished studies were searched on ClinicalTrials.gov, the National Research Register, and Pro-Quest Dissertation Abstracts and Thesis database. RESULTS: Twenty-four studies (15 retrospective, 5 prospective, 2 pilot, and 2 case-control) were included. The results of the analysis carried out on the available literature show that the Invisalign® system is recognized to be a valid alternative to conventional orthodontic treatment in no-extraction cases. The results are influenced by the methods for assessing the effectiveness of this technique and by the comparison bias of the traditional system with the innovative digital system. CONCLUSIONS: Since the introduction of SmartForce and SmartTrack material, the efficacy of the treatment has improved. There is still a shortage of high-quality evidence concerning the treatment modality. In order to make the treatment with the aligners more efficient, a correct management of the ClinCheck® software and a proper use of the biomechanics are necessary. The aligned force-driven system should be taken into account when developing the digital planning.


Assuntos
Inteligência Artificial , Aparelhos Ortodônticos Removíveis , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Software
19.
J Orofac Orthop ; 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38277054

RESUMO

PURPOSE: The purpose of this study was to assess differences in the fundamental mechanical properties of resin-made three-dimensional (3D) printed orthodontic aligners according to the printing orientation. METHODS: Twenty resin 3D-printed dumbbell-shaped specimens and 20 orthodontic aligners were fabricated and postcured in nitrogen. Half of the specimens and aligners were built in horizontal (H), the other half in vertical (V) directions. The dumbbell-shaped specimens were loaded in a tensile testing machine, while parts of the aligners were embedded in acrylic resin, ground, polished, and then underwent instrumented indentation testing (IIT). Mechanical properties that were assessed included the yield strength (YS), breaking strength (BS), plastic strain (ε), Martens hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Data were analyzed statistically with independent t­tests or Mann-Whitney tests at α = 5%. RESULTS: No significant differences were found between specimens or aligners printed either in a horizontal or a vertical direction (P > 0.05 in all instances). Overall, the 3D-printed aligners showed acceptable mechanical propertied in terms of YS (mean 19.2 MPa; standard deviation [SD] 1.7 MPa), BS (mean 19.6 MPa; SD 1.2 MPa), ε (mean 77%; SD 11%), HM (median 89.0 N/mm2; interquartile range [IQR] 84.5-90.0 NN/m2), EIT (median 2670.5 MPa; IQR 2645.0-2726.0 MPa), ηIT (median 27.5%; IQR 25.9-28.1%), and RIT (mean 65.1%; SD 3.5%). CONCLUSION: Printing direction seemed to have no effect on the mechanical properties of 3D-printed resin aligners, which are promising for orthodontic use.

20.
Orthod Craniofac Res ; 27(1): 174-184, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37985447

RESUMO

OBJECTIVE: To investigate the salivary bacterial communities during the first 6-month orthodontic treatment with Clear Aligners (CA) and Fixed Appliances (FA), and its correlation with clinical periodontal parameters. MATERIALS AND METHODS: Saliva and periodontal parameters were sampled from individuals wearing CA or FA before treatment (T0), and after 3- (T3) and 6-month (T6) treatments. Salivary bacterial communities characterized based on the 16S rRNA V3-V4 region were compared between FA and CA and correlated with clinical periodontal parameters. RESULTS: Probing Depth (PD) significantly increased at T6 in the FA group versus T0, whereas it remained stable in the CA group. The Shannon and Pielou indices were significantly higher in the FA group and significantly positively correlated with periodontal inflammation parameters. ß-diversity analysis revealed distinct communities between the FA group and CA group at T6. The relative abundances of 3 genera and 15 species were significantly higher in the FA group. Among the above appliance-type related taxa, bacterial genera Selenomonas, Stomatobaculum, Olsenella and Faecalicoccus and bacterial species Selenomonas_sputigena, Dialister_invisus, Olsenella_profus, Prevotella_buccae, Cryptobacterium_curtum and Clostridium_spiroforme were significantly positively associated with periodontal parameters. CONCLUSIONS: Orthodontic treatments trigger appliance-related salivary bacterial communities, highlighting the importance of developing appliance-orientated periodontal strategies during orthodontic treatments. Salivary bacterial communities harboured by patients wearing FA possess higher bacterial parameters which were associated with increasing PD, PI and Gingival Index.


Assuntos
Microbiota , Aparelhos Ortodônticos , Humanos , RNA Ribossômico 16S/genética , Aparelhos Ortodônticos Fixos , Saliva/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...